 Filename: tfs 211-1.doc
Version 1.9
18.11.2005
VI TELEFILTER
Measurement condition
Filter specification
TFS 211-1
1/5
Ambient temperature: 23 C Input power level: 10 dBm Terminating impedance: Input: 280 || -3,7 pF Output: 280 || -3,7 pF External Coil: 127 nH The filter supports bursted GMSK and EDGE modulation.
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 211-1 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 211 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
Insertion loss (Reference level) Centre frequency Nominal frequency 3dB Bandwidth
arel Relative attenuation fN ... fN 50 kHz ... fN 80 fN 50 kHz ... fN 100 fN 80 ae = amin fc fN
typ. value
4,5 211,0 dB MHz
tolerance / limit
max 6,5 dB
211,0 MHz 25 kHz 211,0 MHz
270 kHz kHz kHz kHz kHz kHz MHz 3,4 -71 -71 -
kHz
min max max max min min min min
215 1,5 2 3 3 25 35 40 5 1,0 -
kHz dB dB dB dB dB dB dB s s
fN 200 fN 400 fN 600 fN 800
kHz kHz kHz kHz
... fN ... fN ... fN ... fN
400 600 800 100
GD
Group delay at fN Group delay ripple
s
max max
fN 50 kHz
Out of band intermodulation Input signals at 211,8 and 212,6 MHz at +10 dBm Input signals at 210,2 and 209,4 MHz at +10 dBm Input power level for less than 1 hour over life time fN 800 kHz ... fN 3 MHz MHz ... fN 100 MHz fN 3 Return loss (S11/S22)
fN 100 kHz
dBm dBm max max max max min
15 25 22 25 10
dBm dBm dBm dBm dB
Operating temperature range Storage temperature range Temperature coefficient of frequency Frequency inversion temperature ca. - 0,036 + 20 C ppm/K
- 5 C ... + 80 C - 40 C ... + 85 C
Generated:
Checked / Approved:
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 211-1.doc
Version 1.9
18.11.2005
VI TELEFILTER
Filter characteristic Filter characteristic 0
-10 -20 -30 magnitude in dB -40 -50 -60 -70 -80 -90 -100 210
Filter specification
TFS 211-1
2/5
0 -1 -2 -3 magnitude in dB -4 -5 -6 -7 -8 -9
10.25 9.5 8.75 8 7.25 6.5 5.75 5 4.25 3.5
210.2
210.4
210.6
210.8 211 211.2 frequency in MHz
211.4
211.6
211.8
212
-10 2.75 210.75 210.8 210.85 210.9 210.95 211 211.05 211.1 211.15 211.2 211.25 frequency in MHz
Construction and pin connection
(All dimensions in mm)
9,1+0,2 - 0,1
7,1 - 0,1
1 5,08 1 3
1,4 +/-0,2
TFS 211-1 T46
Date code
1 2 3 4 5 6 7 8 9 10
Output Ground External Coil Ground Ground Input Ground Ground Ground Ground
+ 0,2
2,54
0,8
8
6
R0,2
1
Date code: T U V ...
Year + week 2005 2006 2007
50 Test circuit
C1 6 1 C2
3 L1
L3 L2
2,4,5,7,8,9,10
L4
6
1
L5
C3
3
L3 C4
2,4,5,7,8,9,10
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
delay in s
Filename: tfs 211-1.doc
Version 1.9
18.11.2005
VI TELEFILTER
Stability characteristics, reliability
Filter specification
TFS 211-1
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel: IEC 286 - 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 2000 min. 300 mm min. 500 mm min. 300 mm
Pull Off Direction
Tape (all dimensions in mm) W : 16,00 0,3 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,10 F : 7,50 0,10 G(min) : 0,60 P2 : 2,00 0,1 P1 : 12,00 0,1 D1(min) : 1,50 +0,1/-0 Ao : 7,60 0,10 Bo : 9,60 0,10 Ct : 13,5
Date Code P1 Po P2
t
Do
G Ct Bo F
Ko Typ PIN Marker D1 Ao
W2 A C N W1
E G W
Reel (all dimensions in mm) A : 330 W1 : 16,4 W2(max) : 22,4 N(min) : 50 C : 13,0
The minimum bending radius is 45 mm.
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 211-1.doc
Version 1.9
18.11.2005
VI TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 211-1
4/5
Conditions Average ramp-up rate (30C to 217C) > 100C > 150C > 217C Peak temperature Time within 5C of actual peak temperature Cool-down rate (Peak to 50C) Time from 30C to Peak temperature
Exposure less than 3C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260C between 10 and 30 seconds less than 6C/second no greater than 300 seconds
Chip-mount air reflow profile Temperature / C
max. 260C
217C
max. 300 s
10 ... 30 s 30 ... 150 s
Time / s
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 211-1.doc
Version 1.9
18.11.2005
VI TELEFILTER
History
Version 1.3 Reason of Changes
Filter specification
TFS 211-1
5/5
Name Dr. Wall
Date 13.07.2000
Change date code to weekly date code. Change filter labelling. Correct tape and reel information. Change stop band attenuation and operating temperature range according to customer's request. Change stop band attenuation in frequency range fN 600 kHz ... fN 800 kHz according to customer requests. Add maximum input power. Add support of bursted GMSK and EDGE modulation. Change power handling, intermodulation and operating temperature range according to customer's request. Change input power level for final test from 0 dBm to 10 dBm ESD limits added Change construction and pin connection. Add filter characteristic. Change stability characteristics to stability characteristics, reliability
1.4 1.5
Dr. Wall Dr. Wall
20.12.2000 22.01.2001
1.6 1.7 1.8. 1.9
Dr. Wall Dr. Wall Strehl Channaa
15.02.2001 27.02.2001 03.09.2004 18.11.2005
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS211-105

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X